4.2 ROLL SENSOR INSTALLATION
Mount the roll sensors to the included roll
sensor brackets using the machine screws and
nylon lock nuts. (Figure 7)
The roll sensors must be mounted
tightly to the brackets.
Figure 7: Mounting the Roll Sensor to the
Roll Sensor Mounting Bracket
When mounting the roll sensors use the
following guidelines and refer to Figure 8.
The smaller the distance between A and B in
Figure 8, the better the performance will be.
Distance A cannot be more than 12”.
a) The roll sensors must not be mounted
below the pivot point.
b) Ensure the roll sensors are sitting relatively
level when the sprayer chassis and boom are
level.
c) Both roll sensors must be mounted with the
circular AMP connector facing towards the
Right-Hand Wing (when looking from the
rear of the sprayer).