Norac UC5-BC-FT03 User Manual

Browse online or download User Manual for Gardening equipment Norac UC5-BC-FT03. NORAC UC5-BC-FT03 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Installation Manual

Fast Aftermarket Installation Manual FT03

Page 2

74.4 Hydraulic Fitting Kit Details (P/N: 44865-09) Item Part Number Name Quantity PictureF02 103839 TEE ADAPTER 6FJXR 6MJT 2F03 104632 TEE ADAPTE

Page 3 - Contents

85 Pre-Install Checklist The pre-install checklist is necessary to check the existing sprayer functionality before the installation. 1. Unfold

Page 4 - 1 Introduction

96 Ultrasonic Sensor Installation 6.1 Ultrasonic Sensor Serial Number Arrangement When installing the UC5 sensors, start with the smallest seria

Page 5 - 2 Technical Specifications

106.2 Ultrasonic Sensor Mounting Guidelines The following guidelines will ensure optimal sensor performance and prevent sensor measurement error.

Page 6 - 3 General UC5 System Layout

116.3 Low Profile Bracket Mounting Guidelines 1. Minimize the distance between the bolts to prevent bending the bracket and prevent the bracket

Page 7 - 4 Kit Parts

126.4 Wing Sensor Installation 1. The wing sensor mounting brackets (B20) are the two brackets with the shorter mounting flange. 2. The sensor

Page 8 - 4.2 Hydraulic Plumbing

136.5 Rainflap Installation Rainflaps are only installed in the wing sensor brackets. 1. Insert one side of the rainflap rod into the pre-bent

Page 9 - 4.3 List of Parts

146.6 Main Lift Sensor Installation 1. Mount the main lift bracket under the valve block between cross member. The bracket should position the

Page 10 - 6 M B - 6 M OR X 90

157 Roll Sensor Installation 7.1 Bracket Assembly 1. Securely mount the roll sensors to the included roll sensor brackets using the #6 machine

Page 11 - 5 Pre-Install Checklist

167.2 Roll Sensor Mounting Guidelines: Center Pivot Booms 1. When mounting the roll sensors, mount one to the boom frame and one to the chassis

Page 12

Printed in Canada Copyright  2014 by NORAC Systems International Inc. Reorder P/N: UC5-BC-FT03-INST Rev B (Fast Aftermarket) NOTICE: NORAC Systems

Page 13

177.3 Roll Sensor Mounting on a Fast Sprayer Figure 18: Roll Sensor Mounting (Viewed from the rear of sprayer)

Page 14

188 Module Installation An optional module mounting bracket kit is available for purchase from NORAC. The mounting brackets are compatible with

Page 15

198.2 Valve Module 1. Install the valve module (E02) to the top of the NORAC valve block. Orient the 6-pin Deutsch (CANbus) connectors towards

Page 16 - 6.5 Rainflap Installation

20 Figure 22: Valve Module Bracket Installation 5. Connect the valve module CANbus to cable C01 from the control module. Route cable C02 from

Page 17

218.3 Input Module 1. Install the input module (E03) on the boom near the Fast valve block. Secure it to the boom using cable ties or optional

Page 18 - 7 Roll Sensor Installation

229 Connecting the Sensors to the CANbus 1. Fasten the 8-way coupler (E11) to the boom with cable ties. 2. Route cable C03 from the input modul

Page 19

2310 Hydraulic Installation Ensure all pressure has been bled from the system before disconnecting any lines or fittings. Hydraulic pressure wi

Page 20

2410.2 Valve Block Mounting 1. Mount the valve block on the center section of the boom as illustrated in Figure 26. 2. Insert the threaded rod

Page 21 - 8 Module Installation

2510.3 Hydraulic Plumbing From this point on in the installation the booms will be inoperative until the hydraulics are fully installed. 1. Aft

Page 22 - 8.2 Valve Module

2611 Software Setup 1. Start up the sprayer and test the sprayer’s functionality. The display terminal does not need to be powered on for the

Page 23

Contents 1 Introduction ... 12

Page 24 - 8.3 Input Module

2712 Cable Drawings 12.1 ITEM C01: 43220-10 - CABLE UC5 NETWORK 14 AWG - 10M 12.2 ITEM C02: 43220-01 - CABLE UC5 NETWORK 14 AWG - 1M

Page 25

2812.3 ITEM C03: 43220-03 - CABLE UC5 NETWORK 14 AWG - 3M 12.4 ITEM C05: 43210-20 - CABLE UC5 NETWORK 18 AWG - 20M

Page 26 - 10 Hydraulic Installation

2912.5 ITEM C10: 43230-04 – CABLE UC5 VALVE DT TO DT

Page 27 - 10.2 Valve Block Mounting

3012.6 ITEM C20: 43240-01 – CABLE UC5 INTERFACE TILT DT

Page 28 - 10.3 Hydraulic Plumbing

3112.7 ITEM C21: 43240-07 – CABLE UC5 INTERFACE MAIN DT (WITH AUX 1 & 2)

Page 29 - 11 Software Setup

3212.8 ITEM C30: 43250-06 – CABLE UC5 BATTERY PIGTAIL FUSED

Page 30 - 12 Cable Drawings

Canada NORAC Systems International Inc. Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921 Shipping Address: 3702 Kinnear Place Saskatoon, SK S7P

Page 31

11 Introduction Congratulations on your purchase of the NORAC UC5 Spray Height Control System. This system is manufactured with top quality comp

Page 32

22 Technical Specifications CAN ICES-3(A)/NMB-3(A) This device complies with part 15 of the FCC Rules. Operation is subject t

Page 33

33 General UC5 System Layout Figure 1 illustrates the general layout of the UC5 system components: Figure 1: General UC5 System Layout

Page 34 - (WITH AUX 1 & 2)

44 Kit Parts 4.1 Kit Overview Figure 2: FT03 System Parts

Page 35

54.2 Hydraulic Plumbing Figure 3: FT03 Hydraulic Plumbing

Page 36

64.3 List of Parts Item Part Number Name QuantityB13 105416 CLAMP ROUND 1-1/4 IN SS 4B17 44972 SENSOR MOUNTING BRACKET LOW PROFILE RAINFLAP 16GA

Comments to this Manuals