SPRA-COUPE 7X60 2008+ Installation Manual Spray Height Control System Improving the competitiveness of Industry and Agriculture through Preci
74 INSTALLATION PROCEDURE 4.1 EXISTING SYSTEM CHECK It is necessary to check the existing system’s functionality before installing the UC4+ Spray
8Table 4: Boom Test Record (WITHOUT UC4+ Spray Height Control system) Working RPM: Boom Trial #1 [Sec] Trial #2 [Sec] Trial #3 [Sec] Avg Time [Sec]
94.3 WING SENSOR INSTALLATION 1. Assemble the Breakaway Sensor Mounting Brackets (B11) as show in Figure 4 and Figure 5. Figure 4: Breakaway Sens
10number on the right hand side (Figure 10). 5. Sensor cables should run through the mounting bracket tube and then behind the member the bracket
11 Figure 9: Wing Sensor Mounting
12Apply a light coating of the supplied Permatex Anti-seize grease to all threaded parts upon installation. Figure 10: Sensor Serial Number Insta
134.4 MAIN LIFT SENSOR INSTALLATION 1. Assemble the main lift sensor bracket (B11) as shown in Figure 11. Figure 11: Main Lift Sensor Bracket 2.
144.5 ROLL SENSOR INSTALLATION Mount the roll sensors to the included roll sensor brackets using the machine screws and nylon lock nuts. (Figure 14
15 Figure 16: Roll Sensor Mounting with Respect to Sprayer Orientation 4.5.1 Boom Roll Sensor Mounting The boom roll sensor (E04) must be mounted t
16 Figure 17: Boom and Chassis Roll Sensors Correctly Mounted 4.5.3 Inverted Roll Sensor Mounting If desired, the Roll sensor may be mounted inver
Printed in Canada Copyright 2005-08 by NORAC Systems International Inc. Reorder P/N: UC4+BC+SC2-INST Rev F (SPRA-COUPE 7X60 2008+) NOTICE NORAC Sys
174.6 HYDRAULIC INSTALLATION WARNING! The hydraulic system creates very high pressure. Before disconnecting any hydraulic lines ensure all press
184.6.2 Valve Mounting 1. Mount the NORAC valve (V01) on the sprayer using the valve mounting bracket (B10). 2. A good mounting location is on th
194.6.3 Hydraulic Plumbing WARNING! From this point in the installation the booms will be inoperative until the electronics are fully installed.
20 Figure 22: How to Tee in the “B” (Raise) Line 24. Install hose H03 onto the tee fitting. 25. Route hose H03 to the NORAC valve block and attach
214.7 ELECTRICAL INSTALLATION 1. Install the UC4+ Control Panel (E01) in the cab of the sprayer. Mount the panel where it will be clearly visible
222. Remove the electrical panel from the right-hand side of the sprayer and locate the access hole on the top right hand side. 3. Connect the UC4
23 It may be easier installing the cables first, while installing the grommet (M15) later. 8. Route C01 through the grommet. Then route the val
24 Figure 29: Cable Configurations: C01, C02, C02B, C03 and C04 18. Connect the 6-pin Tower on the Valve Cable (C03) to the mating 6-pin Shroud on C
254.8 COMPLETING THE INSTALLATION 1. Start up your sprayer and test the sprayer’s functionality. The NORAC Control Panel does not need to be powe
265 ELECTRICAL REFERENCE – CABLE DRAWINGS 5.1 ITEM C01: 44662B – CABLE SENSOR TRUNK 5.2 ITEM C02: 44668 – CABLE SENSOR BRANCH
TABLE OF CONTENTS 1 INTRODUCTION ...
275.3 ITEM C02B: 44664 – CABLE UC4 CAN NODE DUAL
285.4 ITEM C03: 44656D – CABLE VALVE VARIABLE RATE DT
295.5 ITEM C04: 44651 – CABLE VALVE EXTENSION
305.6 ITEM C10: 44650-38 – CABLE UC4 POWER SPRA-COUPE 7000 SERIES <CABLE A>
315.7 ITEM C10: 44650-38 – CABLE UC4 POWER SPRA-COUPE 7000 SERIES <CABLE B>
325.8 ITEM C11: 44658-15 – CABLE UC4 JAM VALVE SPRA-COUPE 7000 SERIES
Canada NORAC Systems International Inc. CALL TOLL FREE: 1-800-667-3921 (306)664-6711 SHIPPING ADDRESS: 3702 Kinnear Place Saskatoon, SK S7P 0A6
11 INTRODUCTION Congratulations on your purchase of the NORAC UC4+ Spray Height Control System. This system is manufactured with top quality comp
22 GENERAL SYSTEM DESCRIPTION Figure 1 depicts the general system layout of the UC4+ Spray Height Control System. Figure 1: System Components an
33 PARTS LISTS The parts that come with your UC4+ System are listed in Table 1. The item number on the left side of this table references each p
4Table 2: 44865-53 - Hydraulics Fittings Kit Item Part Number Name QuantityPictureF02 104369 PLUG - 6MBP 2F03 103345 ELBOW ADAPTER - 6MJ 6FJX90 4F04
5The parts that come with your UC4+ Spray Height Control System are shown below in their general installation configuration. Figure 2: UC4+ Spray H
6 Figure 3: Hydraulic Components The use of dielectric grease is not recommended on any NORAC electrical connections. To ensure all stainless s