4.5 ROLL SENSOR INSTALLATION
Mount the roll sensors to the included roll
sensor brackets using the machine screws and
nylon lock nuts. (Figure 13)
The roll sensors must be mounted
tightly to the brackets.
Figure 13: Mounting the Roll Sensor
When mounting the roll sensors use the
following guidelines and refer to Figure 14.
a) The smaller the distance between A and B
in Figure 14, the better the performance
will be.
Distance A cannot be more than 12”.
b) The roll sensors must not be mounted
below the pivot point.
c) Ensure the roll sensors are sitting relatively
level when the sprayer chassis and boom are
level.
d) Both roll sensors must be mounted with the
circular AMP connector facing towards the
Right-Hand Wing (when looking from the
rear of the sprayer).
Figure 14: Mounting Guidelines for Center Pivot Sprayers
Connectors towards
Right-hand Wing